P/N 03103544-01 is the SIPLACE Type 4108/6108 ceramic placement nozzle for the C&P20 P/M2/P2 nozzle family. Its documented geometry is 11.0 mm overall length with a 0.47 × 0.30 mm pickup tip, and the 4108/6108 is referenced for 0402 component applications.
This gives the nozzle a clear matching role: choose 03103544 when the existing C&P20 P/M2/P2 setup calls for the 4108/6108 geometry and the component application matches that pickup face. A related 4107/6107 ceramic nozzle uses a much larger 1.40 × 0.66 mm tip and a shorter 10.4 mm nozzle length, so the two should not be selected only because they belong to the same 4xxx/6xxx family.
On a 0402 application, the small pickup face makes tip condition and vacuum opening especially relevant. If repeated pickup loss or placement offset appears at a position using 4108/6108, inspect the ceramic tip for contamination or chipping, confirm that the vacuum opening is clear, and check nozzle seating before moving to wider head-side troubleshooting.
The SIPLACE CP20 P2 placement head is one relevant head-generation reference within this nozzle family. Other nozzle geometries and component applications can be compared in the ASM SIPLACE nozzle range.
03103544 4108/6108 Nozzle Specifications
| Part Number | 03103544-01 |
|---|---|
| Nozzle Type | 4108 / 6108 |
| Assembly Level | Complete nozzle |
| Nozzle Material | Ceramic |
| Nozzle Length | 11.0 mm |
| Tip Geometry | 0.47 × 0.30 mm (L × W) |
| Head Family | SIPLACE C&P20 P/M2/P2 |
| Known Component Application | 0402 |
For matching, send the complete 03103544 nozzle marking, C&P20 head identification, clear photos of the pickup face and mounting side, the component being placed, required quantity, and any pickup or placement symptom. If the marking is difficult to read, the 11.0 mm length and 0.47 × 0.30 mm pickup geometry provide additional identification points.
For 4108/6108, the useful purchase check is not simply whether another nozzle fits the same C&P20-family head. The part number, pickup geometry and component application should agree with the existing setup. We can compare those details with the old nozzle photo before quotation to reduce confusion between adjacent 4xxx/6xxx nozzle types.