The ASM SIPLACE 03011582-02 is a 40-way feeder unlock device used in the feeder locking and release mechanism. It should not be treated as a handheld feeder unlocking tool. For maintenance purchasing, the more important question is whether the 03011582 device itself needs replacement or whether the fault is limited to damaged unlocking elements that can be repaired at a lower component level.
One documented service condition for this part is bent or defective unlock pins. When this occurs, replacing the entire feeder unlock device should not automatically be the first decision. The related 03088220 feeder unlock device is referenced for repair work, so the condition of the existing mechanism should be checked before the required purchasing scope is confirmed.
This distinction can help maintenance teams avoid ordering a larger assembly when the fault is localized. If the feeder cannot be released normally, inspect the existing 03011582-02 device and provide clear photos of the unlock mechanism, damaged pins and part label. Our technical team can help determine whether the requirement is for the 03011582-02 device or a related feeder-unlock repair component.
For additional feeder assemblies and repair components, see our ASM SIPLACE feeder and feeder parts.
SIPLACE 03011582-02 Feeder Unlock Specifications
| Part Number | 03011582-02 |
| Product | Feeder Unlock Device 40-Way |
| System Function | Feeder locking and release mechanism |
| Service Condition | Bent or defective unlock pins / unlocking mechanism damage |
| Related Repair Part | 03088220 feeder unlock device |
| Purchase Decision | Replace the 03011582-02 device or repair the affected feeder-unlock component |
Before ordering, send the 03011582-02 label and photos showing the affected unlocking area. If the damage is limited to the feeder-unlock elements, we can help review whether component-level repair is more appropriate than replacing the complete device. For internal purchasing approval, a Formal Specification Confirmation Sheet can also be prepared after the P/N and required repair scope are confirmed.